Power (HP): 1,5 Power (KW): 1,1 Head min. (Mt.): 2 Head max. (Mt.): 18 Capacity min Q. (Lt/Min.): 57,5 Capacity max Q. (Lt/Min.): 516 DNM: 50 Pump weight (Kg): 32 Voltage: single phase 230/240 V - 50 Hz
MOTOR WITH THERMAL OVERLOAD PROTECTOR FOR SINGLEPHASE PUMPS
Power (HP): 1,5 Power (KW): 1,1 Head min. (Mt.): 2 Head max. (Mt.): 18 Capacity min Q. (Lt/Min.): 57,5 Capacity max Q. (Lt/Min.): 516 DNM: 50 Pump weight (Kg): 32 Voltage: single phase 230/240 V - 50 Hz
MOTOR WITH THERMAL OVERLOAD PROTECTOR FOR SINGLEPHASE PUMPS
Power (HP): 0,8 Power (KW): 0,6 Head min. (Mt.): 7,6 Head max. (Mt.): 39 Capacity min Q. (Lt/Min.): 10 Capacity max Q. (Lt/Min.): 40 DNA: 1" DNM: 1" Pump weight (Kg): 8,7 Voltage: single phase 230/240 V - 50 Hz
Power (HP): 0,8 Power (KW): 0,6 Head min. (Mt.): 7,6 Head max. (Mt.): 39 Capacity min Q. (Lt/Min.): 10 Capacity max Q. (Lt/Min.): 40 DNA: 1" DNM: 1" Pump weight (Kg): 8,7 Voltage: single phase 230/240 V - 50 Hz
Power (HP): 0,6 Power (KW): 0,44 Head min. (Mt.): 4 Head max. (Mt.): 26 Capacity min Q. (Lt/Min.): 20 Capacity max Q. (Lt/Min.): 70 DNA: 1" DNM: 1" Pump weight (Kg): 8,1 Voltage: single phase 230/240 V - 50 Hz
Power (HP): 0,6 Power (KW): 0,44 Head min. (Mt.): 4 Head max. (Mt.): 26 Capacity min Q. (Lt/Min.): 20 Capacity max Q. (Lt/Min.): 70 DNA: 1" DNM: 1" Pump weight (Kg): 8,1 Voltage: single phase 230/240 V - 50 Hz
Power (HP): 0,5 Power (KW): 0,37 Head min. (Mt.): 1,2 Head max. (Mt.): 8,8 Capacity min Q. (Lt/Min.): 25 Capacity max Q. (Lt/Min.): 175 DNM: 32 Pump weight (Kg): 5,7 Voltage: single phase 230/240 V - 50 Hz
MOTOR WITH THERMAL OVERLOAD PROTECTOR FOR SINGLEPHASE PUMPS
Power (HP): 0,5 Power (KW): 0,37 Head min. (Mt.): 1,2 Head max. (Mt.): 8,8 Capacity min Q. (Lt/Min.): 25 Capacity max Q. (Lt/Min.): 175 DNM: 32 Pump weight (Kg): 5,7 Voltage: single phase 230/240 V - 50 Hz
MOTOR WITH THERMAL OVERLOAD PROTECTOR FOR SINGLEPHASE PUMPS
Power (HP): 0,75 Power (KW): 1 Head min. (Mt.): 10 Head max. (Mt.): 160 Capacity min Q. (Lt/Min.): 10 Capacity max Q. (Lt/Min.): 160 DNM: ? Pump weight (Kg): 10 Voltage: three phase 230/400 V - 50 Hz
Internal capacitor - 10 mt. cable SCHUKO type plug
Power (HP): 0,75 Power (KW): 1 Head min. (Mt.): 10 Head max. (Mt.): 160 Capacity min Q. (Lt/Min.): 10 Capacity max Q. (Lt/Min.): 160 DNM: ? Pump weight (Kg): 10 Voltage: three phase 230/400 V - 50 Hz
Internal capacitor - 10 mt. cable SCHUKO type plug
Power (HP): 0,5 Power (KW): 0,37 Head min. (Mt.): 4 Head max. (Mt.): 35 Capacity min Q. (Lt/Min.): 5 Capacity max Q. (Lt/Min.): 40 DNA: 1" DNM: 1" Pump weight (Kg): 5,8 Voltage: three phase 230/400 V - 50 Hz
Power (HP): 0,5 Power (KW): 0,37 Head min. (Mt.): 4 Head max. (Mt.): 35 Capacity min Q. (Lt/Min.): 5 Capacity max Q. (Lt/Min.): 40 DNA: 1" DNM: 1" Pump weight (Kg): 5,8 Voltage: three phase 230/400 V - 50 Hz
Power (HP): 0,75 Power (KW): 0,55 Head min. (Mt.): 1 Head max. (Mt.): 11 Capacity min Q. (Lt/Min.): 40 Capacity max Q. (Lt/Min.): 400 DNM: 40 Pump weight (Kg): 16,3 Voltage: single phase 230/240 V - 50 Hz
MOTOR WITH THERMAL OVERLOAD PROTECTOR FOR SINGLEPHASE PUMPS
Power (HP): 0,75 Power (KW): 0,55 Head min. (Mt.): 1 Head max. (Mt.): 11 Capacity min Q. (Lt/Min.): 40 Capacity max Q. (Lt/Min.): 400 DNM: 40 Pump weight (Kg): 16,3 Voltage: single phase 230/240 V - 50 Hz
MOTOR WITH THERMAL OVERLOAD PROTECTOR FOR SINGLEPHASE PUMPS
They perform the function of automatic control of pressure energy levels by acting on the power supply of the electric pump. They are previously calibrated at standard closing and opening contact pressures, but can be calibrated at different pressures thanks to their adjustment device.
They perform the function of automatic control of pressure energy levels by acting on the power supply of the electric pump. They are previously calibrated at standard closing and opening contact pressures, but can be calibrated at different pressures thanks to their adjustment device.